1. QJ type deep well submersible pump power requirements:
(1) The rated frequency is 50 Hz, and the rated voltage of the motor terminal should be guaranteed to be a three-phase AC power supply of 380+5% volts (if the user voltage is 660 volts, special orders are required).
(2) The load power of the transformer should not exceed 75% of its capacity.
(3) When the transformer is far away from the well, the voltage drop of the transmission line should be considered. For motors with a power greater than 45KW, the distance from the transformer to the wellhead should not exceed 20 meters. level, taking into account the line voltage drop.
2. Water quality requirements:
(1) Generally non-corrosive clean water.
(2) The sand content in water is not more than 0.01% (mass ratio).
(3) The pH value of pH is in the range of 6.5-8.5.
(4) The chloride ion content in the water is not more than 400 mg/L.
(5) The hydrogen sulfide content is not more than 1.5 mg/L.
(6) The water temperature should not be higher than 20℃.
3. Wellbore requirements: upright, smooth, without bulge or misalignment of the well pipe, and the inner diameter of the well is not less than the corresponding machine base size.